Pinouts >  HDD and other storage devices connectors
60 pin BURNDY (C-60) connector layout
60 pin BURNDY (C-60) connector
Special invention by IBM for use on IBM RS/6000 and IBM PS/2
Pin Name Dir Description
1 GND --- Ground
2 DB0 <-> Data Bus 0
3 GND --- Ground
4 DB1 <-> Data Bus 1
5 GND --- Ground
6 DB2 <-> Data Bus 2
7 GND --- Ground
8 DB3 <-> Data Bus 3
9 GND --- Ground
10 DB4 <-> Data Bus 4
11 GND --- Ground
12 DB5 <-> Data Bus 5
13 GND --- Ground
14 DB6 <-> Data Bus 6
15 GND --- Ground
16 DB7 <-> Data Bus 7
17 GND --- Ground
18 DPB <-> Data Parity (odd Parity)
19 GND --- Ground
20 GND --- Ground
21 GND --- Ground
22 GND --- Ground
23 GND --- Ground
24 GND --- Ground
25 n/c   Not connected
26 TERMPWR <-> Termination Power
27 GND --- Ground
28 GND --- Ground
29 GND --- Ground
30 GND --- Ground
31 GND --- Ground
32 /ATN <-- Attention
33 GND --- Ground
34 GND --- Ground
35 GND --- Ground
36 /BSY <-> Busy
37 GND --- Ground
38 /ACK <-- Acknowledge
39 GND --- Ground
40 /RST <-> Reset
41 GND --- Ground
42 /MSG --> Message
43 GND --- Ground
44 /SEL <-> Select
45 GND --- Ground
46 /C/D --> Control/Data
47 GND --- Ground
48 /REQ --> Request
49 GND --- Ground
50 /I/O --> Input/Output
51 GND --- Ground
52 res   Reserved
53 res   Reserved
54 res   Reserved
55 res   Reserved
56 res   Reserved
57 res   Reserved
58 res   Reserved
59 res   Reserved
60 res   Reserved

Note: Direction is Device relative Bus (other Devices)

There are no any reports for this pinout! You may rate this document by clicking the button below.

Is this pinout
Source(s) of this and additional information: SCSI FAQ, from Hardware Book
Copyright © 2000-2023 by pinouts.ru team, except user uploaded images.
No portion of this webpage may be reproduced in any form without visible link to pinouts.ru .
Efforts have been made to ensure this page is correct, but it is the responsibility of the user to verify the data is correct for their application.