60 pin Cisco DB connector layout
Разъем 60 pin Cisco DB
This document describes the X.21 cable assembly and pinouts (Data Communications - DCE). Cisco Part#: CAB-X21FC=
60 Pin1 Signal Description Direction 15 Pin Signal
J1-48
J1-47
GND
MODE_2
Shorting group - - -
J1-46 Shield_GND Single - J2-1 Shield GND
J1-28
J1-27
RxD/TxD+
RxD/TxD-
Twisted pair no. 6 -
-
J2-2
J2-9
Transmit+
Transmit-
J1-1
J1-2
CTS/RTS+
CTS/RTS-
Twisted pair no. 1 -
-
J2-3
J2-10
Control+
Control-
J1-11
J1-12
TxD/RxD+
TxD/RxD-
Twisted pair no. 3 -
-
J2-4
J2-11
Receive+
Receive-
J1-9
J1-10
RTS/CTS+
RTS/CTS-
Twisted pair no. 2 -
-
J2-5
J2-12
Indication+
Indication-
J1-24
J1-23
TxC/RxC+
TxC/RxC-
Twisted pair no. 4 -
-
J2-6
J2-13
Timing+
Timing-
J1-15
Shield
Control_GND
-
Twisted pair no. 5 -
-
J2-8
Shield
Control GND
-

Arrows indicate signal direction: - indicates DTE to DCE, and - indicates DCE to DTE.